Nitrogen can be separated from air through our unique separation method by means of a gas separator membrane, and the separated nitrogen with a purity of 99.0%–99.9%) can also be selectively used.

N2 Generator (Air Dryer)

HOME > Products > N2 Generator (Air Dryer)

N2 Generator (Air Dryer)

Introduction

  • This N2 generator separates nitrogen from air using a membrane. The costs of its initial installation and maintenance are more affordable than that of the liquid nitrogen / PSA method.
  • All-in-one type : Regulator + Ultra air filter + Membrane + Flow meter
  • Various nitrogen generators are produced to meet users’ needs, ranging from small generator in hand–soldering units to medium and large ones in soldering robots, ultrasonic soldering equipment, and packaging machines.

Features

  • RoHS truly Applied Pb-Free Soldering
  • N2 Generator equipped with Flow Meter
  • Compact & Simple Design Suitable for Limited Space
  • Membrane type Air Seperation Module
  • Weight, No Noise, Lower Price
  • H2O Pre-Filtering
  • Easy Operating Control

Effectiveness

  • Lead-free processes in response to RoHS
    - Ranges from hand-soldering units to soldering robots
  • Oxidation of the lead-free solder is prevented by creating a
    nitrogen-based atmosphere.
  • The increased degree of wetting and spreading reduces the
    bridge phenomenon.
  • The life of a soldering iron tip increases.
  • The improved work efficiency reduces the
    amount of solder used.
  • The reduced percentage of defects
    decreases the cost of soldering.
  • The fresh quality of food is maintained.
  • Bacterial growth is prevented.
  • The efficacy of medicines is maintained.
  • Chemical reaction to a container is inhibited.
  • Long-term storage of industrial goods (parts)

GN-15S05

N2 concentration (%) 99.9% 99% 98% 97% 96% 95% 90%
Input pressure (kgf/㎤)
3 Generation
rate (ℓ/min)
  0.1 0.3 0.6 0.7 0.8 1.8
5 0.1 0.5 0.7 1.1 1.4 1.6 3.5
7 0.1 0.5 1.2 1.5 1.8 2.1 4.5

130(W) x 140(L) x 430(H)mm
※ The flow data above are measurements by KOFLOC’s mass flowmeter.

GN-15S20

N2 concentration (%) 99.9% 99% 98% 97% 96% 95% 90%
Input pressure (kgf/㎤)
3 Generation
rate (ℓ/min)
0.1 0.6 1 1.3 1.7 2.3 5
5 0.6 1.5 2.2 3 4 5 10
7 1 2.5 3.5 5.3 7 8 12

130(W) x 205(L) x 430(H)mm
※ The flow data above are measurements by KOFLOC’s mass flowmeter.

See more models of 40 type